Metal stud framing takeoff: studs, track, openings and gauges
Interior non-structural steel framing is usually specified to ASTM C645 (the member standard) and installed per ASTM C754. The takeoff itself is simple once you are consistent. The mistakes come from skipping openings, corners and height changes.
1. Organize by wall type
Group walls by type from the partition schedule: stud size, gauge, spacing, height and board layers. Take off linear feet (LF) of each type separately. A 3-5/8" stud at 16" o.c. and a 6" stud at 24" o.c. are different line items.
2. Studs from spacing
Basic count per wall = (wall length in inches ÷ spacing) + 1. Then add:
- Corners and intersections: extra studs at each, according to your standard detail.
- Openings: king or jamb studs on each side of doors and windows (often doubled or heavier gauge at doors, per the spec or detail), plus cripples above the header.
- Ends of walls and transitions where a wall changes height or type.
3. Track
Top and bottom track = 2 × wall LF, plus header and sill track at openings. Deflection (slip) track at the structure counts as its own line item and costs more.
4. Stud length
Studs come in stock lengths, and long walls may need splices or longer special-order material. Note heights above the ceiling to the deck. Walls that go full height to the structure use much more material than walls that stop just above the ceiling.
5. Gauge and height
Allowable height depends on stud depth, gauge, spacing, board layers and the design lateral load. Use the manufacturer's published limiting-height tables for the specified product. Don't guess.
6. Don't forget
- Blocking and backing for casework, grab bars, TVs and equipment.
- Bracing for walls that stop short of the structure.
- Fasteners, powder-actuated pins and screws.
- Waste, using your own historical percentage.
Related: drywall takeoff basics · estimating fire-rated assemblies
Published October 25, 2026. Some links may be affiliate links; see our Affiliate Disclosure.